Õ¹
Ê×Ò³   ÓÊÏä   ÁªÏµÎÒÃÇ   ENGLISH
Èȵãµç»°: 0755-23490731
µã»÷ÕâÀï¸øÎÒ·¢ÏûÏ¢  µã»÷ÕâÀï¸øÎÒ·¢ÏûÏ¢  
     Ê×Ò³        ¹ØÓÚÎÒÃÇ        ÐÂÎŶ¯Ì¬        ²úÆ·ÖÐÐÄ        »ØÊÕ×âÁÞ        ÔÚÏß·´À¡        ÁªÏµÎÒÃÇ
--¹â¹¦ÂʼÆ--Newport 2931-C˫ͨµÀ¹â¹¦ÂʼÆ
¹âÏËÈÛ½Ó»ú
ÌÙ²Ö(Fujikura)¹âÏËÈÛ½Ó»ú
¹ÅºÓ(Furukawa)¹âÏËÈÛ½Ó»ú
סÓÑ(Sumitomo)¹âÏËÈÛ½Ó»ú
ÈÕÐÂ iLsinTech
һŵ INNO
¹âÏËÈÛ½Ó»úµç¼«
µç³Ø ÊÊÅäÆ÷
¹âÏËÈÛ½Ó»ú¸½¼þ
¹âÏ˼оß
ÈÛ½Ó»ú¼ÓÈȯ ¼ÓÈÈÆ÷
¹âÏËÈÛ½Ó»ú°´¼ü
¹âÏËÈÛ½Ó»úЯ´øÏä
ÈÛ½Ó»ú VÐÍ²Û Ñ¹½Å
¹âÏËÇи °þÏßǯ
¹âÏËÇи
¹âÏ˰þÏßǯ ÈȰþǯ
µ¶Æ¬ µ¶Í·
¹âѧ²âÊÔÒDZí
¹âÔ´
¹â¹¦ÂʼÆ
¹â̽ͷ
¶à²¨³¤¼Æ
¹âË¥¼õÆ÷
¹âÆ×·ÖÎöÒÇ
¹â½Ó¿Ú ÊÊÅäÆ÷
UVµã¹âÔ´¹Ì»¯ÏµÍ³
UVµã¹âÔ´
UVµÆÅÝ
UV¹âµ¼¹Ü
¹âÏ˶ËÃæ¼ì²âÆ÷
EXFO
Nikon
VIAVI JDSU
¹âʱÓò·´ÉäÒÇ(OTDR)
°²Á¢(Anristu) OTDR
EXFO OTDR
VIAVI/JDSU OTDR
LCD & Touch Screen
OTDR µç³Ø ÊÊÅäÆ÷
µçÀºÍÌìÏß·ÖÎöÒÇ
¹âÏ˹¤¾ß
¹âÏËʶ±ðÆ÷
¿ÉÊÓ¹ÊÕ϶¨Î»ÒÇ
Êý×ÖͨÐÅ·ÖÎöÒÇ
¹âѧµ÷Õû¼Ü
µØÏ¹ÜÏß̽²âÒÇ
Ê×Ò³ ¹âѧ²âÊÔÒDZí >> ¹â¹¦ÂÊ¼Æ >> Newport 2931-C˫ͨµÀ¹â¹¦ÂʼÆ
¹âѧ²âÊÔÒDZí
Newport 2931-C˫ͨµÀ¹â¹¦ÂʼÆ
Æ·ÅÆ:
  Newport
ÐͺÅ:
  2931-C
±£ÐÞ:
  ¶ÔÓÚ±£ÐÞµÄÏêϸÐÅÏ¢ÁªÏµÎÒÃÇ
¼Û¸ñ:
  £¤.00
¼ò½é:

   ¹¦ÄÜ
Newport 2931-C High-Performance Optical Power Meters

• Measurement rep-rates up to 20 kHz
• True rms measurements
• Power measurements, 100 pW ¨C 40 Watts
• USB data transfer up to 8 Mbps
• Large variety of programmable input and output controlling triggers
• Sophisticated automation capabilities in testing and laboratory applications

Additional Benefits:
• 5.7¡± Graphical TFT LCD, 1⁄4 VGA provides excellent legibility from any angle, in
  any light condition or colored eyewear
• Data storage via internal memory or USB Flash Drive
• Color plotting, statistics and on-board data post-processing
• Analog and digital filtering
• USB and RS-232 computer interfaces
• Trigger in/out control withalarm levels
• Analog bar graph with 10X zoom
• Advanced Programming toolkit -.NET, LabVIEW, High-speed
   Ïêϸ½éÉÜ
Specifications:
Following specifications are preliminary. All efforts were made to accurately
specify the performance of this series of instruments at the time of publication,
please refer to our web site at www.newport.com under Light Test &
Measurement Instruments for updated specifications.

Max Rep Rate
( Photodiode Detectors - P-to-P Power)
20 kHz
Signal Sampling Rate
250 kHz
Current Sensitivity (full-scale)
25 nA ¨C 25 mA
Power Range, Photodiodes
100 pW - 40 W
Resolution
100 fA
Signal-to-Noise, Current Mode (Photodiodes)
100 dB, 5 Hz filter (typ)
Bandwidth (-3 dB) (when using photodiode type detectors)
DC to 180 kHz
Data Storage Buffer (Internal)
250,000 points
Data Storage Buffer (External)
User's USB Flash-Drive dependent
Display Type
5.7¡± Graphical TFT LCD, 1⁄4 VGA
Analog Output (User Selectable)
0¨C0.5 V into 50W, 0¨C1 V into 1MW
0¨C1 V into 50W, 0¨C2 V into 1MW
0¨C2.5 V into 50W, 0¨C5 V into 1MW
0¨C10 V into 1MW
DC Accuracy
<¡À0.1% typical
Peak-to-Peak Accuracy
¡À1% typical
Power Requirements
90¨C240 VAC
Weight [lb (kg)]
11.3 (5.1)
Dimensions (W x H x D) [in. (mm)]
8.50 (216) x 5.25 (133) x 12.11 (308)
Operating Temperature
10¡ãC to 40¡ãC, <80% RH
Storage Temperature
-25¡ãC to 60¡ãC, <90% RH
1) Instrument range is determined by detector used.
2) Specified using model number 818-ST-UV detector at 520 nm and attenuator.
 
User Detector Compatibility
The 1931-C/2931-C Series Power Meters are compatible with Newport's new
918D, 918L and legacy 818 Series Low Power Detectors. When using an 818/CM
Series Low-Power Detector, a 841-DIN adapter is required for compatibility with
the DB-15 connector of the power meter. When using an 818 Series Low-Power
Detector, originally purchased without a calibration module, an 818-SCAL-OPT or
RCAL-10 calibration module is required for calibrated readings using the power
meter. Please contact a Photonics Application Support Engineer for
assistance with selecting the appropriate adapter.
Ê×Ò³      ¹ØÓÚÎÒÃÇ      ÐÂÎŶ¯Ì¬      ²úƷչʾ      »ØÊÕ×âÁÞ      ÔÚÏß·´À¡      ÁªÏµÎÒÃÇ     
°æÈ¨ËùÓÐ © 2006-2020 Sincron Communications   ¼¼ÊõÖ§³Ö£ºÖÚÖÇ´ïÍøÂç     µã»÷ÕâÀï¸øÎÒ·¢ÏûÏ¢  µã»÷ÕâÀï¸øÎÒ·¢ÏûÏ¢